- Contact arrangement
- 1formA( NO)
- Contact resistance
- 100mΩ Max.(at 1A6VDC)
- Rated voltage
- 277VAC
- Max.switching voltage
- 277VAC
- Rated current
- 16A
- Min. recommended contact load
- 1A, 6VDC
- Breaking capacity max.
- 4432VA
- Contact material
- AgSnO₂, AgNi&AgSnO₂
- Frequency of operation
- 360 ops./h
- Operate/release time max.
- 10ms/5ms
- Electrical endurance
- See electrical endurance graph
- Type
- Contact · Load · Cycles
- IEC 61810
- A(NO) · 16A,277VAC,cos φ=1,105℃ · 1×10⁵
- UL 60947‑4‑1 SJ
- A(NO) · 16A,277VAC,cos φ=1,105℃ · 1×10⁵
- GB/T 21711.1‑2023 SJ
- A(NO) · 16A,277VAC,105℃ · 2×10⁴
- Mechanical endurance
- ≥5×10⁶
- Coil voltage range:
- 5 to 24VDC
- Operative range, IEC 61810
- 2
- Coil insulation system according UL
- Class F
- Rated voltage VDC
- Operate voltage VDC · Release voltage VDC · Coil resistance Ω (1±10%) · Rated coil powers mW
- 5
- ≤3.75 · ≥0.25 · 47 · 530
- 6
- ≤4.5 · ≥0.3 · 68 · 530
- 9
- ≤6.75 · ≥0.45 · 153 · 530
- 12
- ≤9 · ≥0.6 · 272 · 530
- 18
- ≤13.5 · ≥0.9 · 611 · 530
- 24
- ≤18 · ≥1.2 · 1087 · 530
- between open contacts
- 1000VAC
- between contact and coil
- 4000VAC
- between contact and coil 〈Clearance〉
- ≥8.0mm(actual)
- between contact and coil 〈Creepage〉
- ≥8.0mm(actual)
- Material group of insulation parts
- IIIa
- Tracking index of relay
- PTI 175V/PTI 250V
- Ambient temperature
- ‑40℃ to +105℃
- IEC61810
- RTII‑ fluxproof RTIII‑Sealed type washable
- Weight
- Approx. 5.9g